You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
On the bodies and rods config file is a strange "tdb" field, which shifts all other fields "to the right". Thus VIV is enabled, and the coefficients are messed up.
From bodies and rods:
LineType Diam MassDenInAir EA BA/-zeta EI tbd Can Cat Cdn Cdt
from viv:
LineType Diam MassDenInAir EA cIntDamp EI Cd Ca CdAx CaAx Cl
Good eye @sanguinariojoe, it looks like it is only for the nylon line (11 input values), while the cable and buoyancy are still at 10. I'm not sure why that is in there, but given the supposed tbd coefficient is zero I think it should be fine to remove it
Activity
RyanDavies19 commentedon Nov 25, 2025
Good eye @sanguinariojoe, it looks like it is only for the nylon line (11 input values), while the cable and buoyancy are still at 10. I'm not sure why that is in there, but given the supposed tbd coefficient is zero I think it should be fine to remove it
sanguinariojoe commentedon Nov 25, 2025
Fixed on #349