2 changes: 1 addition & 1 deletion README.md
Original file line number Diff line number Diff line change
Expand Up @@ -165,7 +165,7 @@ rack; a dashed border means egress only. Full topology and data flow in
│ ├── adr/ # 11 architecture decision records
│ └── runbooks/ # deploy, add device, rotate creds, certs, key backup,
│ # purge, restore the firewall, ship firewall logs,
│ # enable suricata
│ # enable suricata, fit the UPS battery
└── Makefile # make help
```

Expand Down
2 changes: 1 addition & 1 deletion docs/observability.md
Original file line number Diff line number Diff line change
Expand Up @@ -105,7 +105,7 @@ boot check.
| --- | --- |
| `host.rules.yaml` | Instance down, predictive disk fill, memory, load, clock skew, reboots |
| `network.rules.yaml` | SNMP reachability, pf not running, state table, switch links, iLO hardware |
| `ups.rules.yaml` | On battery, low battery, runtime, load, temperature |
| `ups.rules.yaml` | On battery, low battery, runtime, load, temperature. No pack is fitted, so most of these read values the management card fabricates — see [`runbooks/fit-the-ups-battery.md`](runbooks/fit-the-ups-battery.md) |
| `containers.rules.yaml` | Restart loops, OOM kills, memory, throttling, and the stack watching itself |
| `watchdog.rules.yaml` | One rule that always fires, so that its absence is detectable |

Expand Down
2 changes: 2 additions & 0 deletions docs/roadmap.md
Original file line number Diff line number Diff line change
Expand Up @@ -99,13 +99,15 @@ what left this one unfireable for months.
The management card fabricates a healthy pack. **The `UpsSelfTestFailed`
silence must be deleted the moment the pack is fitted, not left to expire** —
the issue carries the command and the reasoning.
→ [runbook](runbooks/fit-the-ups-battery.md)
- **[#110](https://github.com/Gerrrt/HomeLab/issues/110) Rack the shelf switch.**
A 1U vented shelf in **U4**, carrying the unmanaged switch `prometheus` and
`oracle` hang off. **Buy it with the UPS pack above, not after** — both shelf
machines are laptops, so on a mains cut they stay running and go deaf while the
switch between them and the network has no battery at all. Spec settled at the
rack on 2026-08-21; the spare ProDesk from
[#92](https://github.com/Gerrrt/HomeLab/issues/92) racks here too, powered off.
→ [runbook](runbooks/fit-the-ups-battery.md)
- **[#94](https://github.com/Gerrrt/HomeLab/issues/94) Decide what `oracle` is
for.** A dual-core A6-9200 with 4 GB and a 5400 rpm disk — too little for
anything demanding, and a candidate for the jobs that need a machine that is
Expand Down
231 changes: 231 additions & 0 deletions docs/runbooks/fit-the-ups-battery.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,231 @@
# Runbook: Fit the UPS battery and rack the shelf switch

**One rack visit, in an order that matters — and one alert that has to be
un-silenced by hand at the right moment.**

`mjolnir` has no battery pack fitted. A mains loss is an immediate hard shutdown
of the entire rack, and `docs/security.md` lists it under "Not currently
defended". The management card does not report the missing pack; it fabricates a
healthy one, so every alert keyed on charge, runtime or alarm count is quietly
dead. Only `UpsSelfTestFailed` and `UpsBatteryUnproven` in `ups.rules.yaml` can
see the real condition, because they read the one value the card will not fake.

The pack alone is not the whole fix.

## Why the shelf is part of this, not a follow-up

`prometheus` and `oracle` hang off an unmanaged TP-Link that has no battery at
all. Both are laptops with their own batteries, so on a mains cut they stay
*running* and go *deaf* — the monitoring host survives the event it exists to
observe and cannot report it.

Fitting the pack protects the rack and does nothing for that switch. Racking the
switch in U4 and moving it onto UPS power is what closes the gap, which is why
[#93](https://github.com/Gerrrt/HomeLab/issues/93) and
[#110](https://github.com/Gerrrt/HomeLab/issues/110) were bought together and
are done together.

## Before you start

Two boxes, checked before either is opened:

- **The cartridge is an APCRBC115.** Not a compatible-with listing that turns
out to be a different form factor once the front bezel is off.
- **The shelf matches the spec measured at the rack on 2026-08-21:** 4-post
frame, square mounting holes, a **full 1U shelf with rear support** rather
than a cantilever, and **cage nuts plus screws** — most shelves include them,
not all.

Depth is not a constraint. U4 is empty only because nothing had been chosen for
it, so there is no service clearance to preserve.

You will also need the stack up on `prometheus`, and access to the management
card's web UI for `mjolnir` at `10.0.99.10`.

## 1. Record the baseline before touching anything

The point of this step is that the after-state is *provably* different rather
than assumed to be. Capture what the card claims today:

```bash
for m in upsBatteryStatus upsEstimatedChargeRemaining \
upsEstimatedMinutesRemaining upsBatteryVoltage \
upsAlarmsPresent upsTestResultsSummary; do
printf '%-32s ' "$m"
curl -sG http://localhost:9090/api/v1/query \
--data-urlencode "query=${m}{device=\"mjolnir\"}" |
python3 -c 'import json,sys; r=json.load(sys.stdin)["data"]["result"]; print(r[0]["value"][1] if r else "no data")'
done
```

Expected on a UPS with no pack fitted — every one of these is derived, not
measured:

| Metric | Reads | Means |
| --- | --- | --- |
| `upsBatteryStatus` | `2` | batteryNormal |
| `upsEstimatedChargeRemaining` | `100` | percent |
| `upsEstimatedMinutesRemaining` | `63` | minutes of runtime it does not have |
| `upsBatteryVoltage` | `480` | 48.0 V |
| `upsAlarmsPresent` | `0` | no alarm raised |
| `upsTestResultsSummary` | `4` | aborted — **the one honest value** |

Write the numbers down. In step 5 you compare against them, and a charge still
reading exactly `100` with a runtime still at exactly `63` is the signature of a
card that is still fabricating because it does not see the new pack.

Query Prometheus rather than reaching for `snmpget`: the community would sit on
your command line where `ps` can read it. `scripts/snmp-verify.sh` exists for
the cases that genuinely need the wire, and reads the credential from SOPS.

## 2. At the rack, in this order

1. **Rack the 1U vented shelf in U4.** Cage nuts front and rear, screws through
the shelf, rear support engaged.
2. **Move the TP-Link onto the shelf** and re-seat its uplink to port 3 of the
main switch, plus the runs to `prometheus` and `oracle`.
3. **Move the TP-Link's power onto a UPS-fed outlet.** This is the step that
closes #110. A switch that has been relocated onto a shelf but left on a wall
socket is tidier and no better protected — the laptops still go deaf on a
mains cut.
4. **Rack the cold-spare ProDesk from
[#92](https://github.com/Gerrrt/HomeLab/issues/92) beside it**, cabled for
its cold-spare role and **left powered off**. A spare that is plugged in and
on the network is exposed to whatever took the primary.
5. **Fit the APCRBC115 pack** last, per the Smart-UPS front-bezel procedure, and
confirm the card comes back with the battery-replacement date reset.

## 3. Delete the silence — immediately, not on expiry

`UpsSelfTestFailed` is silenced in Alertmanager until **2026-09-20**
(`54f1715c-e57b-4322-8a6d-5435bc8e1bd8`). It routes on `category=power` to the
`urgent` receiver with `group_wait: 0s` and `repeat_interval: 30m`, so leaving
it firing meant paging every half hour about a condition already known — which
is how an urgent receiver stops being read. The silence was correct while
nothing could be done about it.

It stops being correct the moment the pack is in. Between fitting and 20
September it would suppress `UpsSelfTestFailed` on a UPS that can finally report
honestly — **including a new pack that is faulty or badly seated**, which is
precisely the thing you have just introduced and most want to hear about.

```bash
curl -sS -X DELETE \
http://localhost:9093/api/v2/silence/54f1715c-e57b-4322-8a6d-5435bc8e1bd8
```

Confirm it is gone rather than merely expired:

```bash
curl -sS http://localhost:9093/api/v2/silences |
python3 -c 'import json,sys; [print(s["id"], s["status"]["state"]) for s in json.load(sys.stdin)]'
```

Delete it **before** the self-test, not after. Run in the other order, the one
result you most need to see is the one that is suppressed.

## 4. Run one self-test, and read it from both ends

From the management card's diagnostics page, start a single self-test. Then
confirm the result twice:

- **On the NMC** — the page that read "Refused — internal fault" should now
report a pass.
- **In Prometheus** — because the NMC agreeing with itself proves nothing about
the scrape path:

```bash
curl -sG http://localhost:9090/api/v1/query \
--data-urlencode 'query=upsTestResultsSummary{device="mjolnir"}'
```

`upsTestResultsSummary` must read `1` (donePass). The full enumeration, from
`ups.rules.yaml`:

| Value | Meaning |
| --- | --- |
| `1` | donePass |
| `2` | doneWarning |
| `3` | doneError |
| `4` | aborted |
| `5` | inProgress |
| `6` | noTestsInitiated |

Anything in `2`–`4` means `UpsSelfTestFailed` should fire within 5 minutes, and
it now will, because you deleted the silence first. That is the system working.

## 5. Confirm the fabricated metrics became real

Re-run the loop from step 1 and compare against the baseline. Charge, runtime
and voltage should now reflect an actual pack — a partially charged new
cartridge typically reads *below* 100% for the first hours, which is itself
evidence the value is measured.

If they are byte-for-byte identical to the baseline, the card is still
fabricating. Treat that as "the pack is not seen", not as "the pack is fine and
the numbers happen to match" — go back to seating and the battery-replacement
date before believing anything else on the dashboard.

## 6. Enable scheduled self-tests

A value of `1` is the *last* result, not a fresh one. If the NMC stops testing
entirely the metric simply stops changing, and nothing in `ups.rules.yaml`
detects that — `upsTestStartTime` is `sysUpTime`-relative and does not survive
an agent restart, so it is not a usable staleness signal.

Scheduled tests on the device are the control. Enable them on the NMC so
`UpsBatteryUnproven` — which reads `min_over_time`/`max_over_time` over 7 days
rather than a `for:` that a Prometheus restart would reset — has live evidence
to read instead of an absence of it. The reasoning is argued in full in the
header of `ups.rules.yaml`; this step is where it gets acted on.

Do not go on running self-tests by hand to keep the metric warm. A test
transfers the load to battery, and on a pack that is weak that is the outage the
alert exists to warn about.

## 7. What becomes true afterwards

`UpsBatteryLow`, `UpsChargeLow` and `UpsRuntimeCritical` become meaningful rules
rather than decorative ones, reading values that finally correspond to hardware.
**No rule edits are needed** — the file was written so that its rules become
correct the moment a pack exists, and nothing in it changes today.

## If something goes wrong

**The self-test still reports `4` (aborted).** Do not re-create the silence. A
still-aborted test with a pack fitted is a finding: check the cartridge is fully
seated and its connector latched, and reset the battery-replacement date on the
NMC so the card re-evaluates. If it persists, the alert firing every 30 minutes
is the correct state of the world until it is resolved.

**The self-test reads `5` (inProgress) and stays there.** `UpsSelfTestFailed` is
bounded below `5` deliberately so a test in flight does not trip it. Wait for it
to settle before concluding anything.

**`prometheus` or `oracle` came back unreachable after the shelf move.** The
uplink to port 3 of the main switch, not the UPS. Nothing in this runbook
touches VLAN configuration.

## Only when all of the above passes — flip the documents

Several files currently assert, correctly, that there is no battery. They become
wrong the moment this runbook succeeds, and they are a separate commit made
*after* verification, not before:

| File | What changes |
| --- | --- |
| `stacks/observability/grafana/dashboards/ups-power.json` | Delete the "No battery is installed in this UPS" banner panel; strip "(fabricated — no battery fitted)" from the six panel titles and their descriptions |
| `stacks/observability/prometheus/rules/ups.rules.yaml` | Rewrite the header comment. The rules themselves do not change |
| `docs/security.md` | The "Mains power loss" row in the threat table, and the "The UPS reports a battery it does not have" section |
| `README.md` | The UPS dashboard screenshot alt text, and the "current top items" paragraph. Re-capture with `make screenshots` |
| `docs/hardware.md` | The 1U shelf into the rack table at U4, and into Accessories |
| `docs/network.md` | The TP-Link note — now racked and on UPS power |
| `docs/roadmap.md` | Move #93 and #110 into Done. Existing entries stay as written; the roadmap is a record |

One coupling to know about before you start editing: **deleting the banner panel
changes the dashboard's panel count**, and `scripts/check_docs.py` asserts every
panel count quoted in prose against the live JSON. Move the numbers in the same
commit or CI will fail. Run `make validate` before pushing.

Then close [#93](https://github.com/Gerrrt/HomeLab/issues/93) and
[#110](https://github.com/Gerrrt/HomeLab/issues/110).
Loading