Find circuits by any id when topology is unavailable, and show unknown readings as unknown - #22

Merged
cayossarian merged 6 commits into
mainfrom
fix/opaque-ids-and-unknown-readings
Oct 9, 2026
Merged

cayossarian merged 6 commits into
mainfrom
fix/opaque-ids-and-unknown-readings

Conversation

@cayossarian

Copy link
Copy Markdown
Member

Two fixes.

When the integration cannot report the panel's layout, the card still finds every circuit from its power sensor. That fallback reads the
entity registry, and took a circuit only from a unique id with a long hex segment. It now takes one circuit from each circuit power sensor. The
circuit id is everything between span_{serial}_ (the serial lower-cased, as the integration writes it) and the _power suffix, _ included.
A circuit whose power sensor is disabled is no longer found through its energy or current sensors, which before also made one of them its
"power" entity.

A reading the panel has not published shows as "--", never 0. An unknown or unavailable state read as 0, so the card drew 0 W, 0 A
and 0 % and added the term to sums. One helper, readNumber, now reads a state as a number or null:

  • a null reading shows as "--", is not styled as production, and sorts after every measured circuit in the list;
  • a circuit whose current has no reading draws no utilization, even when the current monitor still holds a figure;
  • the header's sum of the circuits leaves out an unknown term and marks itself partial (stat-partial);
  • every header reading starts unknown rather than 0;
  • MonitoringPointInfo.utilization_pct is typed number | null, as the integration sends it.

A published 0 stays a reading.

The last commit rebuilds dist/.

Checks

  • npm test: 561 passed in 56 files (520 in 53 before)
  • npm run typecheck, npm run lint, node scripts/validate-i18n.mjs: clean
  • npm run build: clean
  • pre-commit hooks (prettier, eslint, typecheck, markdownlint, i18n) passed on every commit

…y is unavailable

The entity-registry fallback, used when the integration cannot report the panel's layout, took a circuit only from a unique id with a long hex segment, so circuits with other ids were missed. It now takes one circuit from each circuit power sensor.
An unknown or unavailable power, current or battery state read as 0, so the card drew 0 W, 0 A and 0 % for a measurement nobody took and added it to sums as 0. One helper now reads a state as a number or null. A null reading shows as "--", is not production, draws no utilization, and sorts after every measured circuit in the list. The header's sum of the circuits leaves out an unknown term and marks itself partial, and every header reading starts unknown rather than 0.
The current monitor can report 0 % before its first reading and keeps its last figure after the current sensor goes unavailable, so a circuit showed "--" A beside a utilization figure. A circuit whose current sensor has no reading now draws no utilization, whatever the monitor holds.
The fallback used when the integration cannot report the panel's layout took the circuit id as everything after the second `_` segment, which is wrong for a serial that contains `_`. It now strips `span_{serial}_` with the serial lower-cased, as the integration writes it, and the `_power` suffix, and falls back to the second segment only when the unique id does not start with the panel's serial. The changelog entry now says which discovery changed.
@cayossarian
cayossarian merged commit d8ee6b5 into main Oct 9, 2026
2 checks passed