…m it arxml/can-full.arxml describes the can-full bench as an AUTOSAR R19-11 System Template: bench.dbc's frames unchanged, six new DC-DC frames on 0x310-0x315 (E2E profiles 1, 2 and 5, a container I-PDU with short headers, a multiplexed I-PDU, a SecOC profile 1 secured I-PDU), UDS as DCM I-PDUs over CanTp, XCP as general-purpose I-PDUs. It loads strictly, without warnings or dangling references, in autosar-data and cantools. tools/arxml2c.py generates the DC-DC's C tables from it: ids, timing, signal layouts and scaling, E2E and SecOC parameters. `just arxml` runs it and the firmware workflow fails when the tables and the ARXML disagree. A description the core cannot send (big-endian signals, long or little-endian container headers, unaligned SecOC fields, other E2E profiles, raw ranges beyond float precision) fails generation rather than the node.
lib/autosar is a sans-IO core (signal packing, E2E profiles 1, 2 and 5 per the PRS, the container short header, multiplexed segments, the SecOC trailer) and its Zephyr side: one thread sends a schedule of PDUs on their ARXML timing through lib/can, earliest deadline first and below the application threads, and AES-128 CMAC comes from PSA Crypto (mbedtls and tf-psa-crypto join the west allowlist). The DC-DC maps each model sample onto the generated tables, one build function per PDU; a PDU the ARXML adds without one does not compile. CommunicationControl stops them with its other normal messages. nodes/full takes the snippet, adding 200 frames/s (about 5 % of 500 kbit/s). The SecOC key is RFC 4493's example key: public on purpose, a demo key. full.elf grows by 10.8 KB of text and 13.3 KB of RAM: the 3 KB thread stack, 8 KB of AES tables, PSA state.
suites/autosar tests the DC-DC as a bench tests an AUTOSAR ECU, with cantools reading arxml/can-full.arxml: ids, lengths and cycles as described; E2E profile 1 by hand (cantools has none), 2 and 5 by cantools; the container's PDUs in turn; the multiplexed PDU's alternatives; the SecOC MAC verified with the key (cryptography); every value equal to DCDC_Status's of the same sample; UDS on the CanTp addressing and flow control the ARXML gives; 0x28 silencing the PDUs. It records the bus with candump, out of process, and fails when the host dropped frames rather than blaming the node. can-full runs it in CI and on hardware. ztests check the core against the PRS E2E example tables, RFC 4493's CMAC examples and signal scaling at its edges. The UDS suite's self-test test now reads its socket during the 2 s routine: at the added 200 frames/s the idle socket overflowed and dropped the final response, which udsoncan had received.
On hardware the 600 s coexistence soak failed on one missing DAQ sample while the node's counters were clean. With candump -d the record shows why: the suite's candump, writing to a file, dropped 501 frames in four bursts, while a second candump on the same run writing to tmpfs dropped none of 1.86 M frames and saw every DAQ sample. A write waiting on the disk stalls candump until its socket overflows. frames.recording() now has candump write into a pipe the test process drains, records every frame when given no ids, and fails as an incomplete record when the host drops frames instead of as a lost sample. The soak records through it; its assertions are unchanged.
P0A94-00 DC/DC converter performance (overtemperature), P0A09-00 status circuit low (input undervoltage), P0A08-00 status circuit (output overcurrent), U0111-00 lost communication with the battery energy control module (BMS_Limits missing). A scan tool shows the generic text instead of manufacturer codes. Before: 0x1A0098, 0x1A0116, 0x1A0219, 0xC11187.
SAE J1979 services 0x01 (support bitmaps, MIL and DTC count, OBD standard, the node's PIDs), 0x02 (freeze frame 0 from snapshot record 0x01 of the first confirmed DTC), 0x03/0x07/0x0A (confirmed, pending, permanent DTCs as 2-byte codes), 0x04 (clear) and 0x09 (VIN from DID 0xF190, CALID, CVN, ECU name) on the UDS identifiers. Unsupported requests get nothing, physically or functionally. SAE J1979-2 on the same core: DIDs 0xF400 + PID, 0xF501, 0xF8xx; ReadDTCInformation 0x42, 0x55, 0x56; ClearDTC group 0xFFFF33. CONFIG_ZELOS_UDS_OBD, on with the UDS server. The DC-DC's PIDs are a four-row table, each a formula over one of its DIDs, so the freeze frame reports them from the snapshot: 0x1F run time, 0x42 module voltage, 0x46 ambient temperature, 0x5B pack life. New for every build: a DTC confirmed with its indicator requested is permanent. ClearDTC and 0x04 leave it; it goes once its test has passed in three consecutive operation cycles.
A scan tool's view of the DC-DC: single frames on 0x7DF, an ISO-TP stack per responder for the flow control a multi-frame response needs. PIDs walked from the bitmaps and checked against DCDC_Status; MIL and count; a lost BMS pending, confirmed and in the freeze frame; a permanent DTC surviving 0x04 and 0x14; the VIN by multi-frame; J1979-2 DIDs and 0x19 reports equal to the legacy services; silence to unsupported requests. Its fault tests play the BMS, so beside the bench's BMS they skip; CI also runs the suite on the image alone, as it runs can_raw.
DTCs follow 13 CCR 1968.2 (d)(2.2)-(2.5) on the one DTC memory UDS and OBD share. An operation cycle is still one boot (any ECUReset ends it). - Two-cycle confirmation: a failure stores pendingDTC and the freeze frame; confirmedDTC, warningIndicatorRequested and permanent follow when it fails in a second tested cycle (CONFIG_ZELOS_UDS_DTC_CONFIRM_CYCLES, 2). - The MIL is warningIndicatorRequested: it stays on while the test passes and goes off after three passed cycles (..._HEALING_CYCLES), taking the permanent DTC with it. confirmedDTC then ages out after 40 cycles without a failure (..._AGING_CYCLES), one cycle being one warm-up cycle here. - A permanent DTC whose MIL is off, after a clear or a power loss, goes after one cycle in which its test ran and never failed. core_init() takes the permanent set to restore after a power loss. - Freeze frames: the first with the pending code (records 0x00 and 0x01, OBD freeze frame 0), the second (0xF0) at the first failure of each later cycle; erased with an unconfirmed pending code or the aged confirmed one. OBD freeze frame 0 belongs to the DTC stored first, not the lowest index. - PID 0x01: MIL from warningIndicatorRequested; comprehensive components supported and complete. CONFIG_ZELOS_UDS_OBD_VIN: only one ECU reports the VIN. J1979-2: DID 0xF810 = 0x01; ReadDataByIdentifier answers the DIDs it supports and 0x31 only if none is (every DID, ISO 14229-1); 0x19 0x42 reports severity class 0x02 and applies the severity mask; 0x19 0x55 records are DTC and status, 4 bytes; 0x19 0x56 with no DTC in the group is 0x31; 0x19 0x04 records 0x00 and 0xF0 carry DIDs 0xF400 + PID; OBD requests are never answered 0x13 or 0x21. Legacy: requests mixing availability and data PIDs, more than 6 PIDs or 3 freeze frame pairs get nothing; 0x09 takes up to 6 availability infotypes. The uds suite's DTC test follows: pending before confirmed, the MIL kept until three passed cycles, two failed cycles in extended data 0x01, three snapshot records in 0x19 0x03, and a multi-DID read keeps the supported DIDs. Renode zeroes RAM on a reset (its reset reloads the ELF), so the test needing the memory to survive one skips there.
13 CCR 1968.2 (g)(4.4.6)(C): no power loss erases a permanent DTC. With CONFIG_ZELOS_UDS_NVS (default with OBD-II and a storage partition) the permanent DTCs are one Zephyr Memory Storage (ZMS) entry, their 3-byte numbers, read at start and handed to the core, which restores them when the RAM memory was lost. ZMS, not NVS: NVS takes sectors of 64 KB at most, and the H753's erase sector is 128 KB. A work queue at the lowest application priority rewrites the entry when the set changes: the flash driver busy-waits, and nothing of the application, XCP or the server may wait on it. The uds snippet moves the H753's storage partition to flash bank 2: a sector erase stalls fetches from its own bank, and the code runs from bank 1.
Each new test names the clause it checks: - a fault is pending in its first failing cycle, confirmed with the MIL and permanent in its second (13 CCR 1968.2 (d)(2.2.1)-(2.2.2), (d)(2.2.5)); - the MIL goes off after three passing cycles, the code stays confirmed and the permanent code goes with the MIL ((d)(2.3.2), (d)(2.4), (d)(2.5.1)); - a permanent code survives 0x04 and 0x14 0xFFFF33 and goes after one passing cycle ((g)(4.4.6)(C), (d)(2.5.2)(A)); - the freeze frame is stored with the pending code, and J1979-2 record 0x00 carries it as DIDs 0xF400 + PID ((d)(2.2.7), (g)(4.3.1)); - 22 F810 = 0x01 (ISO 15765-4:2021 6.1.1), a multi-DID read answers the supported subset, malformed OBD requests get no 0x13 ((g)(3.4.2)(A)), 19 56 of an empty group is 0x31, mixed availability and data PIDs get nothing (AUTOSAR SWS_Dcm_00943/00972). 0x19 0x42 and 0x55 are read with the suite's own byte layout (severity, DTC, status; DTC, status), no longer through udsoncan, whose 0x55 parser expects a severity byte. Operation cycles end with ECUReset; the fault tests play or silence BMS_Limits, so they run against any DC-DC responder that watches it, not only the node, and skip under Renode where a reset loses RAM.
The reset macro reloaded the ELF on every reset, including the firmware's own reboot, and LoadELF zero-fills the RW segment that holds .bss and .noinit. Every ECUReset under Renode was therefore a power loss: the DTC memory kept in .noinit was erased, and the lifecycle tests that end operation cycles with 0x11 0x01 had to skip there. The ELF now loads once, when the machine is created. A machine reset keeps memory but puts the vector table offset back to 0, where Renode's part has an empty ITCM, so the CPU halts with SP and PC 0; the macro sets it to the part's boot address (flash, 0x08000000) beside the SysTick frequency. The obd suite's three cycle tests and the uds suite's operation-cycle test no longer skip under Renode. Renode bench, full.elf alone: obd 15 passed (was 12 + 3 skipped), uds 60 passed + 4 timing skips (was 59 + 5). The can-full bench is unchanged at 100 passed, 15 skipped: these tests silence the BMS, and skip beside the bench's.
ISO 15765-4:2005 Table 7: the external test equipment sends one flow control with block size 0 and STmin 0. The suite's scan tool sent can-isotp's default block size, 8. Padding is the tester's choice; the scan tool now pads with 0xCC, as the UDS client does.
ReadDTCInformation 0x1A of record 0x91 (in-use ratio) or 0x92 (test results) answers 0x31: no DTC of the DC-DC has a ratio or test-result monitor (comprehensive components only, 13 CCR 1968.2 (g)(4.5.1), (d)(5.1); SWS_Dcm_01609), nothing functionally. 0x06 and 0x1A of those records are OBD requests, so a malformed one gets no 0x13 and none gets 0x21. The obd suite asserts that a J1979-2 scan tool reads what a legacy one does: readiness (01 01 = F501 = F401), the support bitmaps, the DTC lists, and no test results, ratios or PID 41 either way.
PID 42 is the live rail voltage; two reads at different times differed by more than the bound under a loaded bench. F442 must lie in the span of the PID 42 reads before and after it.
09 06 and 22 F806 computed the CRC-32 of the whole download window (64 KB on the DC-DC) on every request: in any session, without security, functionally, while a routine was pending, and under core_lock. The control loop takes that lock on every DTC report, so each such request could hold it off for the CRC's duration, with the UDS thread raised to its priority meanwhile. The CVN is now computed at start, and again on the first read after an erase or a TransferData write. Both need the programming session with its security level unlocked, so outside one no request computes a CRC; inside, a read computes at most one per such change.
seal() took core_lock and returned, so an ECUReset right after a DTC confirmation could reboot mid zms_write: a half-programmed flash word, possibly an ECC error that fails zms_mount on every later boot, after which permanent DTCs are never stored again. seal() now finishes the queued or running write before taking core_lock, which the write takes too, and then takes a lock the write holds through the flash access, so a write begun in between is waited out and none begins after. The reboot waits only for writes queued or begun before it.
… span Frame 0's PID 5B was compared with itself whenever the pack voltage was known; it is now checked against the snapshot's pack voltage, encoded as the node does. F446 in a multi-DID read is live temperature: it must lie within a degree of two PID 46 reads around it, not equal one taken later. Dropped asserts other tests already make: F400 and F440 against PID 00 and 40, F40C's 0x31, and the silence of 06 00 and 09 08.
The memory window holds the last control cycle's state, so a read right after the previous test restored the setpoint could still see 12.34 V.
The old check subtracted one second from PID 1F and failed on a responder up for less than a second.
With CONFIG_ZELOS_UDS_NVS, a storage partition that does not mount, or a write of the permanent DTCs that fails, sets P062F-00 (SAE J2012 internal control module EEPROM error; 0x062F00, legacy 0x062F) through the normal DTC path: it reports on 0x03, 0x0A and 0x19 0x42 and lights the MIL. AUTOSAR NvM/Dem report a failed non-volatile block the same way, as an ECU-internal DTC. The node runs on with its permanent DTCs in RAM, and the existing log line stays. CCR 1968.2 (g)(4.4.6)(C) requires permanent DTCs to survive a power loss; this is the ECU saying it cannot. - Confirmed at its first failure: its pending state would live only in RAM, which a power loss takes with the store broken, so a two-cycle rule would never confirm it. - Never written to flash: the mask the store holds and compares is the node's DTCs only, so its own permanent bit cannot retrigger the write that failed. - In the core only from its first failure until it ages out or is cleared, as the node's last DTC (the glue appends it with zelos_uds_core_extend()), and kept across a reset (zelos_uds_core_kept()): while the store works, the supported DTC list and every report are unchanged. - A mount, or a write that succeeds, passes it; it heals as any other. ztest test_store_failure_dtc: P062F appended cleared, the node's DTC memory kept, confirmed + MIL at one failure (0x03, 0x07, PID 0x01, 0x19 0x42), its permanent bit, kept over a reset and passing with the MIL kept, and gone after a power loss with a working store.
The same helper, now shared by the uds suites.
zms_mount() ran in zelos_uds_start(), on the main thread before the node's threads: a blank storage partition (first boot, or a garbage collection cut short) erases a 128 KB sector there, so CAN started 1-2 s late. The mount is now the first job of the store's work queue, at the lowest application priority, submitted once the UDS thread runs: the node starts at once. - Until the mount, the permanent DTCs are those in RAM and requests are answered from them as always (no 0x21 on OBD); writes queue behind the mount, and a reboot waits out a mount in progress as it does a write. - After a power loss, flash's permanent DTCs join when it has mounted (zelos_uds_core_restore(): applied only if the memory started cleared, as zelos_uds_core_init()'s argument was). - A mount that fails sets P062F then, as before. ztest test_permanent_dtcs_restored_after_the_mount: none before the mount, flash's after it on a power-on, RAM's kept over a reset.
A second tester on 0x7E0/0x7E8 flow-controls the node's responses too. Zephyr's ISO-TP (v4.4.2) took its FC, arriving while the FF or a block's last CF was still pending, as the one due: it released the next CF with one in flight, and the M_CAN priority queue sends equal identifiers by buffer index, so CFs left out of order. An FC reaching the receiver aborted the request being received, or discarded one just received. Either way the tester timed out. A west patch, applied when just updates the workspace, makes both sides ignore an FC they are not waiting for (ISO 15765-2) and keeps one frame in flight. Two HIL tests drive the node by hand with a second tester's FC after every frame of ours.
python-can marks every frame from this host as not received, and on the Renode bench the node is on this host: the hand reader saw nothing.
tkeairns
force-pushed
the
feat/autosar-ecu
branch
from
October 19, 2026 18:16
634291b to
d0fd7d6
Compare
Contributor
Author
|
Folded into #18 (feat/autosar-ecu, rebased on main): both commits are there as 43557f4 and e5e6d78, with a fix on top (3a29180: tx_backlog counted before can_send(), so a completion that beats its return cannot leave it at 1). The CommunicationControl failures under Renode were not the patch: both tests waited bound(0.5) (2.5 s on a Renode bench) in a non-default session with no request, and a Renode bench catching up on time it fell behind runs up to ~2x the host, so S3 (5 s of node time) ended the session inside the wait. Reproduced on unpatched firmware with --time-scale 12; fixed in the tests (d0fd7d6, TesterPresent through the wait). Details in #18. |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
What
zephyr/patches/zephyr/isotp-stray-fc.patch, applied bywest patch applywhenjustupdates the workspace (_westnow hasheswest.yml,zephyr/patches.ymland the patches). Zephyr v4.4.2 ISO-TP:tx_backlog); any other FC is ignored (ISO 15765-2 9.8.3), and one CF is in flight at a time (the M_CAN priority queue sends equal identifiers by buffer index, not in queue order).testing/suites/uds/test_dcdc_node.py:test_a_second_testers_flow_control_is_ignoredandtest_a_request_survives_a_second_testers_flow_controldrive the node by hand with a second tester's FC (DLC 3, BS 0) after every frame of ours. The hand reader filters the node's frames by id only (on vcan every frame from the host readsis_rx=False).Why
A second tester on 0x7E0/0x7E8 (a bench condition on the HIL bus) flow-controls the node's responses too. Unpatched, its FC released a CF with one in flight (CFs out of order on the wire) or aborted a request: the tester timed out (UDS P2 timeouts in the HIL soak).
How tested
just twisterwith the patchbus_health(the other tester's controller errors, not the node)response cut short: 6 of 50 bytes), fail with any part of it alone (receiver hunk; sender FC rule; FF count + one CF in flight), pass with all of itOpen (why this is not in #18)
On the can-full Renode bench, with the whole patch,
test_communication_control_stops_the_broadcastandtest_communication_control_silences_the_pdusfailed in 3 of 4 runs; without the patch or with any part of it they passed in 7 of 7. Both run before the stray-FC tests. Node-side logging of every UDS request (debug run) shows:28 01the node's clock ran 5.0 s while about 0.8 s of host time passed (the test sleeps 0.5 s), so S3 expired (tick sess 3->1) and the next28 00met the default session (NRC 0x7F). Renode advances idle virtual time faster than real time.communication = 1(session 3) from the28 01on, yet DCDC_Status kept arriving on vcan for about 0.3 s.So the failures are timing on the simulator, but the patch changes them from never to usually, and the mechanism is not proven. Needed before merge: a node-time check of the second case (frame times from the node, not the host) and either a test fix that holds in node time or a patch change.