| title: Siemens S7 Nodes | ||
| metaTitle: "Siemens S7 Nodes" | ||
| navTitle: Siemens S7 | ||
| navOrder: 4 | ||
| meta: | ||
| description: A suite of nodes for reading, writing, and monitoring data on Siemens S7-200, S7-300, S7-400, S7-1200, S7-1500 and LOGO! PLCs over the S7 protocol. | ||
| --- | ||
|
|
||
| # Siemens S7 Nodes | ||
|
|
||
| A suite of nodes for reading, writing, and monitoring data on Siemens S7 PLCs, from S7-300 and S7-400 to S7-1200, S7-1500 and LOGO!, using the S7 communication protocol (S7comm). | ||
|
|
||
| ## Overview | ||
|
|
||
| The Siemens S7 nodes connect FlowFuse flows to Siemens PLCs over Ethernet. They read and write data blocks, markers, inputs, outputs, counters and timers, watch addresses for changes, discover the data blocks on a PLC, and import tag lists exported from TIA Portal and STEP 7, so you can work with named tags rather than raw addresses. | ||
|
|
||
| Each connection can use one of three backends: | ||
|
|
||
| - **nodes7** (default): pure JavaScript, nothing to compile, works anywhere Node-RED runs. | ||
| - **snap7**: the native Snap7 library. Adds block listing, CPU status and CPU control, and a few data types nodes7 does not support. | ||
| - **sim**: a built-in simulated PLC, for building and testing flows without hardware. | ||
|
|
||
| This is a **FlowFuse Certified Node**. Unlike community nodes, which vary in quality and can go unmaintained without warning, FlowFuse vets Certified Nodes for quality, security, and support, and maintains them on an ongoing basis. [Read more about Certified Nodes](/blog/2025/07/certified-nodes-v2/). | ||
|
|
||
| ::note | ||
| The Siemens S7 nodes are not available by default. They are part of the FlowFuse Edge Certified Nodes catalogue, which is part of the **FlowFuse Edge** offering. Please contact our sales team at [Contact us](/contact-us/) to learn more or to request access. | ||
| :: | ||
|
|
||
| ## What is S7 communication? | ||
|
|
||
| S7 communication (S7comm) is the protocol Siemens SIMATIC PLCs use to exchange data with HMIs, SCADA systems, engineering tools and other PLCs. It runs over ISO-on-TCP (RFC 1006) on TCP port 102 typically, so an Ethernet-connected PLC needs no extra gateway or OPC server. | ||
|
|
||
| S7comm reads and writes by absolute address: a data block number and byte offset (`DB1,REAL0`, or `DB1.DBD0` in TIA Portal notation), or a memory area such as markers (`MW10`), inputs (`I0.1`) and outputs (`QW2`). It does not use the symbolic tag names of TIA Portal, which is why S7-1200 and S7-1500 PLCs need a couple of settings changed before they can be reached this way (see [Requirements](#requirements)). | ||
|
|
||
| ## Supported Hardware | ||
|
|
||
| | PLC family | Default rack / slot | Notes | | ||
| |------------|---------------------|-------| | ||
| | **S7-1500** | 0 / 1 | Enable PUT/GET access; use non-optimized data blocks | | ||
| | **S7-1200** | 0 / 1 | Enable PUT/GET access; use non-optimized data blocks | | ||
| | **S7-300** | 0 / 2 | | | ||
| | **S7-400** | 0 / 3 | Use the slot of the CPU in the rack | | ||
| | **S7-200** | 0 / 1 | Ethernet-connected models | | ||
| | **LOGO!** | - | Connects by TSAP instead of rack and slot, e.g. local `01.00` and remote `02.00` | | ||
|
|
||
| ## Requirements | ||
|
|
||
| - Node.js 18 or later | ||
| - Node-RED 2.0 or later | ||
| - Access to the FlowFuse Edge Certified Nodes catalogue (part of the **FlowFuse Edge** offering) | ||
| - Network access from your FlowFuse instance or device to the PLC on TCP port 102 | ||
|
|
||
| ### Preparing an S7-1200 or S7-1500 | ||
|
|
||
| These PLCs block external S7 access by default. In TIA Portal: | ||
|
|
||
| 1. In the PLC's device configuration, under **Protection & Security > Connection mechanisms**, tick **Permit access with PUT/GET communication from remote partner**. | ||
| 2. For each data block you want to read or write, open its **Properties > Attributes** and untick **Optimized block access**, then compile. Markers, inputs and outputs do not need this. | ||
| 3. Download the changes to the PLC. | ||
|
|
||
| ### The snap7 backend | ||
|
|
||
| The default nodes7 backend needs nothing extra. The optional snap7 backend uses the native `node-snap7` module, which is installed alongside the nodes where it can be built for your platform. If it is not available, the snap7 option reports that it is missing and the nodes7 backend continues to work. | ||
|
|
||
| ## Installation | ||
|
|
||
| Because these nodes are part of the FlowFuse Edge Certified Nodes catalogue, which is part of the **FlowFuse Edge** offering, make sure your account has access before installing. Contact our [sales team](/contact-us/) if you don't. | ||
|
|
||
| ::note | ||
| Newly installed nodes are picked up automatically, no restart needed. Restart is only required when you update a node that's already installed: restart any remote instance or hosted instance running the previous version. | ||
| :: | ||
|
|
||
| ### Install via the Palette Manager (recommended) | ||
|
|
||
| 1. Open the **Palette Manager** from the top-right menu in the FlowFuse editor. | ||
| 2. Switch to the **Install** tab. | ||
| 3. Search for the **FlowFuse Edge Certified Nodes** collection. | ||
| 4. Locate `@flowfuse-certified-nodes/s7` and click **Install**. | ||
|
|
||
| After installation, the nodes appear under the **S7 Suite** category in the palette, and the connection is set up in an **s7-config** configuration node. | ||
|
|
||
|
Contributor
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. We should also add a variable addressing table similar to the one in this node README.
Contributor
Author
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Added in 2d5b42b As stated in the OP, this is very much an MVP so that we have docs on day one - my hope (🤞) is that someone (you 😉) will improve them to the same standard as the CIP Suite 😄 in a future iteration.
Contributor
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Thanks, Steve! Yes, I’ll improve them in a future iteration |
||
| ## Nodes in the Suite | ||
|
|
||
| | Node | Type | Description | | ||
| |------|------|-------------| | ||
| | **s7-config** | Config | The connection to one PLC: host, port, rack and slot (or TSAPs), backend, timeouts and automatic reconnection. Connection settings can come from environment variables, and flows can connect, disconnect, reconnect or ask for the connection status. | | ||
| | **s7-read** | In/Out | Read one or many addresses as a single value, an object keyed by address or label, a raw buffer, a structure defined by a schema, or an array of bits. Addresses can be set in the node or taken from the message, flow, global context or an environment variable. Import tag lists from TIA Portal (`.xlsx`, `.xml`, `.sdf`) or STEP 7 (`.csv`, `.cfg`). | | ||
| | **s7-write** | In/Out | Write single values, arrays, strings, several addresses at once, or a whole structure. | | ||
| | **s7-trigger** | Out | Poll addresses at an interval and send a message when a value changes, with rising and falling edge detection for bits and a deadband for analog values. | | ||
| | **s7-browse** | In/Out | Discover the data blocks and memory areas on a PLC, or read them from a STEP 7 `.cfg` export without a live connection. | | ||
| | **s7-control** | In/Out | Start, stop or cold-start the PLC CPU. snap7 backend only, and many S7-1200 and S7-1500 PLCs refuse these commands over PUT/GET. | | ||
|
|
||
| ## Variable addressing | ||
|
|
||
| Addresses use the nodes7 format, which differs a little from TIA Portal and STEP 7. The TIA Portal form is accepted too, so `DB1.DBD8` and `DB1,DWORD8` read the same value, and both forms can be mixed in one node. | ||
|
|
||
| ### Data blocks | ||
|
|
||
| | Address | TIA Portal equivalent | Value in Node-RED | Description | | ||
| |---------|-----------------------|-------------------|-------------| | ||
| | `DB5,X0.1` | `DB5.DBX0.1` | boolean | Bit 1 of byte 0 of DB 5 | | ||
| | `DB23,BYTE1` | `DB23.DBB1` | number | Byte 1 of DB 23 (0 to 255) | | ||
| | `DB100,CHAR2` | `DB100.DBB2` | string | Byte 2 of DB 100 as a character | | ||
| | `DB42,INT4` | `DB42.DBW4` | number | Signed 16-bit integer at byte 4 of DB 42 | | ||
| | `DB57,WORD4` | `DB57.DBW4` | number | Unsigned 16-bit integer at byte 4 of DB 57 | | ||
| | `DB13,DINT6` | `DB13.DBD6` | number | Signed 32-bit integer at byte 6 of DB 13 | | ||
| | `DB19,DWORD6` | `DB19.DBD6` | number | Unsigned 32-bit integer at byte 6 of DB 19 | | ||
| | `DB21,REAL8` | `DB21.DBD8` | number | 32-bit floating point number at byte 8 of DB 21 | | ||
| | `DB21,LREAL12` | - | number | 64-bit floating point number at byte 12 of DB 21 | | ||
| | `DB2,STRING10.20` | - | string | `STRING[20]` starting at byte 10 of DB 2 | | ||
| | `DB1,DTL0` | - | Date | `DTL` at byte 0 of DB 1, as server local time. Use `DTLZ` if the PLC keeps UTC | | ||
| | `DB1,DT12` | - | Date | `DATE_AND_TIME` at byte 12 of DB 1, as server local time. Use `DTZ` if the PLC keeps UTC | | ||
|
|
||
| The TIA Portal column shows where the value lives. Typed in that form, `DBW` always reads as an unsigned `WORD` and `DBD` as an unsigned `DWORD`, so use the nodes7 form for `INT`, `DINT` and `REAL`. | ||
|
|
||
| A string takes 2 bytes more than its length: the first byte holds the maximum length and the second the current length. When writing to a string that is already declared in the PLC, the length can be left off (`DB2,STRING10`). | ||
|
|
||
| ### Inputs, outputs and markers | ||
|
|
||
| | Address | TIA Portal equivalent | Value in Node-RED | Description | | ||
| |---------|-----------------------|-------------------|-------------| | ||
| | `I1.0` | `I1.0` | boolean | Bit 0 of byte 1 of the inputs | | ||
| | `Q2.1` | `Q2.1` | boolean | Bit 1 of byte 2 of the outputs | | ||
| | `M3.2` | `M3.2` | boolean | Bit 2 of byte 3 of the markers | | ||
| | `IB4` | `IB4` | number | Byte 4 of the inputs (0 to 255) | | ||
| | `QB5` | `QB5` | number | Byte 5 of the outputs (0 to 255) | | ||
| | `MB6` | `MB6` | number | Byte 6 of the markers (0 to 255) | | ||
| | `IW10` | `IW10` | number | Unsigned 16-bit integer at byte 10 of the inputs | | ||
| | `QW12` | `QW12` | number | Unsigned 16-bit integer at byte 12 of the outputs | | ||
| | `MW14` | `MW14` | number | Unsigned 16-bit integer at byte 14 of the markers | | ||
| | `ID16` | `ID16` | number | Unsigned 32-bit integer at byte 16 of the inputs | | ||
| | `QD20` | `QD20` | number | Unsigned 32-bit integer at byte 20 of the outputs | | ||
| | `MD24` | `MD24` | number | Unsigned 32-bit integer at byte 24 of the markers | | ||
| | `C1` | `C1` | number | Counter 1 (snap7 backend only) | | ||
| | `T2` | `T2` | number | Timer 2 (snap7 backend only) | | ||
|
|
||
| ### Arrays | ||
|
|
||
| A number after the offset reads that many values as an array, and a write takes an array of exactly that many values. For a bit, the second number is the count. | ||
|
|
||
| | Address | Description | | ||
| |---------|-------------| | ||
| | `DB1,INT20.3` | 3 `INT` values starting at byte 20 of DB 1, an `Array[0..2] of Int` | | ||
| | `DB1,REAL40.10` | 10 `REAL` values starting at byte 40 of DB 1 | | ||
| | `DB1,X10.3.8` | 8 consecutive bits starting at bit 3 of byte 10 of DB 1, an `Array[0..7] of Bool` | | ||
| | `MB20.4` | 4 bytes starting at byte 20 of the markers | | ||
| | `M10.0.16` | 16 consecutive bits starting at bit 0 of byte 10 of the markers | | ||
|
|
||
| ### Data types and backends | ||
|
|
||
| The nodes7 backend reads and writes `BOOL`, `BYTE`, `CHAR`, `WORD`, `INT`, `DWORD`, `DINT`, `REAL`, `LREAL`, `STRING`, `DT`, `DTZ`, `DTL` and `DTLZ`. These types need the snap7 backend: | ||
|
|
||
| - `USINT`, `UINT`, `UDINT`, `LINT` and `ULINT` | ||
| - `DATE`, `TIME`, `TIME_OF_DAY`, `S5TIME` and `DATE_AND_TIME` | ||
| - reading `WSTRING` (nodes7 can write it) | ||
| - counters and timers | ||
|
|
||
| The sim backend supports every type. If the nodes7 backend is given a type it does not support, the node reports an error that names the address. | ||