r202639: the snapshot reports the panel's breaker position range, and a model reported as UNKNOWN reads as no model.

  • New fields SpanPanelSnapshot.first_position / last_position (int | None): the reported model's range from PANEL_POSITIONS_BY_MODEL; the occupied range where the model is not known; None on the flat schema. Only a range: no position is filled in. A panel whose circuits occupy spaces outside its model's range keeps the table's range and is reported once at WARNING.
  • The reference tree's three single-space circuits move from spaces 1-3 into the model's range (manifest and recapture from the pinned emitter, in their own commit); four tests follow the new spaces.
  • info/model UNKNOWN reads as model = None, sizes the panel 0 without a per-snapshot warning, and is not model drift.
  • New field SpanPanelSnapshot.publishes_solar_roles: True where any circuit declares connection/feeds-role.
  • Six acceptance tests now pass and leave the expected-failure registry.

Checks:

  • pytest tests -q: 1550 passed, 7 skipped, 14 xfailed (40 new; 6 registry rows removed).
  • pre-commit run --all-files: all hooks pass (ruff, black, mypy, pylint, bandit, vulture, coverage 96.53%).

The manifest placed three single-space circuits on spaces 1 to 3, which
are outside the breaker positions a panel of the reference's model has.
They move to 9, 10 and 11, marked as a third deliberate divergence from
the emitter's example, and parent_child_tree.json is recaptured from the
pinned ebus-panel-sim 0.8.0. Only those three info/spaces values and the
wall-clock $description versions change.

The tests that pinned the old space, or added a circuit at a position
outside the model's range, follow.

Part of the spanos3/r202639/03 batch 2 work.
… for an unknown model

SpanPanelSnapshot.first_position and last_position say which breaker
positions the panel has. They come from the reported model through
PANEL_POSITIONS_BY_MODEL, and from the occupied spaces where the model is
not known. They are only a range: nothing is filled in over it. Where a
panel's circuits occupy spaces outside its model's range, the range stays
the table's and the adapter warns once for that panel, naming the model,
the range and the occupied extremes.

A model reported as UNKNOWN names no model. It reads as None, sizes the
panel 0 without a warning on every snapshot, and is not model drift.

SpanPanelSnapshot.publishes_solar_roles is True where any circuit
declares connection/feeds-role. The acceptance tests these satisfy leave
the expected-failure registry.

Part of the spanos3/r202639/03 batch 2 work.
Resolved: SchemaOneAdapter.__init__ keeps the per-device grace state that
replaced the feed-wait fields, and adds the once-per-panel positions flag.
@cayossarian
cayossarian merged commit 1a924eb into prerelease/3.8 Oct 9, 2026
5 checks passed